| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration. |
| A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system. |
| Asio C++ Library before 1.13.0 lacks a fallback error code in the case of SSL_ERROR_SYSCALL with no associated error information from the SSL library being used. |
| Filament is a collection of full-stack components for accelerated Laravel development. All Filament features that interact with storage use the `default_filesystem_disk` config option. This allows the user to easily swap their storage driver to something production-ready like `s3` when deploying their app, without having to touch multiple configuration options and potentially forgetting about some. The default disk is set to `public` when you first install Filament, since this allows users to quickly get started developing with a functional disk that allows features such as file upload previews locally without the need to set up an S3 disk with temporary URL support. However, some features of Filament such as exports also rely on storage, and the files that are stored contain data that should often not be public. This is not an issue for the many deployed applications, since many use a secure default disk such as S3 in production. However, [CWE-1188](https://cwe.mitre.org/data/definitions/1188.html) suggests that having the `public` disk as the default disk in Filament is a security vulnerability itself. As such, we have implemented a measure to protect users whereby if the `public` disk is set as the default disk, the exports feature will automatically swap it out for the `local` disk, if that exists. Users who set the default disk to `local` or `s3` already are not affected. If a user wants to continue to use the `public` disk for exports, they can by setting the export disk deliberately. This change has been included in the 3.2.123 release and all users who use the `public` disk are advised to upgrade. |
| The BigFix SaaS's HTTP responses were missing some security headers. The absence of these headers weakens the application's client-side security posture, making it more vulnerable to common web attacks that these headers are designed to mitigate, such as Cross-Site Scripting (XSS), Clickjacking, and protocol downgrade attacks. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to
unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious
user, having physical access, sets the radio to the factory default mode. |
| Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched. |
| Improper isolation of shared resources on a system on a chip by a malicious local attacker with high privileges could potentially lead to a partial loss of integrity. |
| The CS5000 Fire Panel is vulnerable due to a default account that exists
on the panel. Even though it is possible to change this by SSHing into
the device, it has remained unchanged on every installed system
observed. This account is not root but holds high-level permissions that
could severely impact the device's operation if exploited. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an
attacker to execute unauthorized commands when a system’s default password credentials have not been
changed on first use. The default username is not displayed correctly in the WebHMI interface. |
| Insecure initial password configuration issue in SEIKO EPSON Web Config allows a remote unauthenticated attacker to set an arbitrary password and operate the device with an administrative privilege. As for the details of the affected versions, see the information provided by the vendor under [References]. |
| Improper isolation in some Intel(R) Processors stream cache mechanism may allow an authenticated user to potentially enable escalation of privilege via local access. |
| An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup. |
| Incorrect configuration of replication security in the MariaDB component of the infra-operator in YAOOK Operator allows an on-path attacker to read database contents, potentially including credentials |
| Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges. |
| Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of
confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the
product does not correctly initialize all data. |
| Enabled IP Forwarding feature in B&R Automation Runtime versions before 6.0.2 may allow remote attack-ers to compromise network security by routing IP-based packets through the host, potentially by-passing firewall, router, or NAC filtering. |