| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| The passwordless login mechanism in CGFIDO from Changing Information Technology has an Authentication Bypass vulnerability, allowing remote attackers with regular privileges to send a crafted request to switch to the identity of any user, including administrators. |
| Improper Restriction of Excessive Authentication Attempts vulnerability in WebFactory Ltd Captcha Code allows Functionality Bypass.This issue affects Captcha Code: from n/a through 2.9. |
| The system exposes several endpoints, typically including "/int/" in their path, that should be restricted to internal services, but are instead publicly accessible without authentication to any host able to reach the application server on port 443/tcp. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| The IEEE 802.11 standard sometimes enables an adversary to trick a victim into connecting to an unintended or untrusted network with Home WEP, Home WPA3 SAE-loop. Enterprise 802.1X/EAP, Mesh AMPE, or FILS, aka an "SSID Confusion" issue. This occurs because the SSID is not always used to derive the pairwise master key or session keys, and because there is not a protected exchange of an SSID during a 4-way handshake. |
| Entrust Instant Financial Issuance (IFI) On Premise software (formerly referred to as CardWizard) versions 5.x, prior to 6.10.5, and prior to 6.11.1 contain an insecure .NET Remoting exposure in the Legacy Remoting Service that is enabled by default. The service registers a TCP remoting channel with SOAP and binary formatters configured at TypeFilterLevel=Full and exposes default ObjectURI endpoints such as logfile.rem, photo.rem, cwPhoto.rem, and reports.rem on a network-reachable remoting port. A remote, unauthenticated attacker who can reach the remoting port can invoke exposed remoting objects to read arbitrary files from the server and coerce outbound authentication, and may achieve arbitrary file write and remote code execution via known .NET Remoting exploitation techniques. This can lead to disclosure of sensitive installation and service-account data and compromise of the affected host. |
| A security issue exists within the 5032 16pt Digital Configurable module’s web server. Intercepted session credentials can be used within a 3-minute timeout window, allowing unauthorized users to perform privileged actions. |
| A vulnerability exists in the NodeRestriction admission controller in Kubernetes clusters where node users can delete their corresponding node object by patching themselves with an OwnerReference to a cluster-scoped resource. If the OwnerReference resource does not exist or is subsequently deleted, the given node object will be deleted via garbage collection. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| A vulnerability was found in Digistar AG-30 Plus 2.6b. It has been classified as problematic. Affected is an unknown function of the component Login Page. The manipulation leads to improper restriction of excessive authentication attempts. The complexity of an attack is rather high. The exploitability is told to be difficult. The vendor was contacted early about this disclosure but did not respond in any way. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| Nedap Librix Ecoreader
is missing authentication for critical functions that could allow an
unauthenticated attacker to potentially execute malicious code. |
| A vulnerability in Palantir's Aries service allowed unauthenticated access to log viewing and management functionality on Apollo instances using default configuration. The defect resulted in both authentication and authorization checks being bypassed, potentially allowing any network-accessible client to view system logs and perform operations without valid credentials. No evidence of exploitation was identified during the vulnerability window. |
| SSL-VPN MFA Bypass in SonicWALL SSL-VPN can arise in specific cases due to the separate handling of UPN (User Principal Name) and SAM (Security Account Manager) account names when integrated with Microsoft Active Directory, allowing MFA to be configured independently for each login method and potentially enabling attackers to bypass MFA by exploiting the alternative account name. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information. |