| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Quest KACE Systems Management Appliance (SMA) 13.0.x before 13.0.385, 13.1.x before 13.1.81, 13.2.x before 13.2.183, 14.0.x before 14.0.341 (Patch 5), and 14.1.x before 14.1.101 (Patch 4) allows unauthenticated users to replace system licenses through a web interface intended for license renewal. Attackers can exploit this to replace valid licenses with expired or trial licenses, causing denial of service. |
| The embedded web server lacks authentication and access controls, allowing unrestricted remote access. This could lead to configuration changes, operational disruption, or arbitrary code execution depending on the environment and exposed functionality. |
| A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is known. |
| It is possible to bypass the administrator login screen on SolaX Cloud. An attacker could use parameter tampering to bypass the login screen and gain limited access to the system. |
| It is possible to bypass the clipping level of authentication attempts in SolaX Cloud through the use of the 'Forgot Password' functionality as an oracle. |
| A vulnerability has been identified in SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.4.24), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.4.24), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.4.24). Affected devices do not properly authenticate configuration connections. This could allow an unauthenticated remote attacker to access the configuration data. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to change time of the device, which means the device could behave differently. |
| microCLAUDIA in v3.2.0 and prior has an improper access control vulnerability.
This flaw allows an authenticated user to perform unauthorized actions on other organizations' systems by sending direct API requests. To do so, the attacker can use organization identifiers obtained through a compromised endpoint or deduced manually.
This vulnerability allows access between tenants, enabling an attacker to list and manage remote assets, uninstall agents, and even delete vaccines configurations. |
| Spring Security Aspects may not correctly locate method security annotations on private methods. This can cause an authorization bypass.
Your application may be affected by this if the following are true:
* You are using @EnableMethodSecurity(mode=ASPECTJ) and spring-security-aspects, and
* You have Spring Security method annotations on a private method
In that case, the target method may be able to be invoked without proper authorization.
You are not affected if:
* You are not using @EnableMethodSecurity(mode=ASPECTJ) or spring-security-aspects, or
* You have no Spring Security-annotated private methods |
| This vulnerability exists in Meon KYC solutions due to missing restrictions on the number of incorrect One-Time Password (OTP) attempts through certain API endpoints of login process. A remote attacker could exploit this vulnerability by performing a brute force attack on OTP, which could lead to gain unauthorized access to other user accounts. |
| Due to missing authentication, SAP HANA 2.0 (hdbrss) allows an unauthenticated attacker to call a remote-enabled function that will enable them to view information. As a result, it has a low impact on the confidentiality but no impact on the integrity and availability of the system. |
| The SAP Internet Communication Framework does not conduct any authentication checks for features that need user identification allowing an attacker to reuse authorization tokens, violating secure authentication practices causing low impact on Confidentiality, Integrity and Availability of the application. |
| immich is a high performance self-hosted photo and video management solution. Prior to 1.132.0, immich is vulnerable to account hijacking through oauth2, because the state parameter is not being checked. The oauth2 state parameter is similar to a csrf token, so when the user starts the login flow this unpredictable token is generated and somehow saved in the browser session and passed to the identity provider, which will return the state parameter when redirecting the user back to immich. Before the user is logged in that parameter needs to be verified to make sure the login was actively initiated by the user in this browser session. On it's own, this wouldn't be too bad, but when immich uses the /user-settings page as a redirect_uri, it will automatically link the accounts if the user was already logged in. This means that if someone has an immich instance with a public oauth provider (like google), an attacker can - for example - embed a hidden iframe in a webpage or even just send the victim a forged oauth login url with a code that logs the victim into the attackers oauth account and redirects back to immich and links the accounts. After this, the attacker can log into the victims account using their own oauth credentials. This vulnerability is fixed in 1.132.0. |
| Password guessing limits could be bypassed when using LDAP authentication. |
| DuraComm SPM-500 DP-10iN-100-MU
lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device. |
| Yealink RPS before 2025-06-04 lacks SN verification attempt limits, enabling brute-force enumeration (last five digits). |
| Delta Electronics DIAView has an authentication bypass vulnerability. |
| A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |