| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) is vulnerable to Broken Access Control in initial configuration wizard.cgi endpoint. Malicious attacker can change admin panel password without authorization. The vulnerability can also be exploited after the initial configuration has been set.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| A vulnerability was found in rowboatlabs rowboat up to 8096eaf63b5a0732edd8f812bee05b78e214ee97. It has been rated as critical. Affected by this issue is the function PUT of the file apps/rowboat/app/api/uploads/[fileId]/route.ts of the component Session Handler. The manipulation of the argument params leads to missing authentication. The attack may be launched remotely. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. It is expected that this issue will be fixed in the near future. |
| General Bytes Crypto Application Server (CAS) beginning with version 20201208 prior to 20220531.38 (backport) and 20220725.22 (mainline) contains an authentication bypass in the admin web interface. An unauthenticated attacker could invoke the same URL used by the product's default-installation / first-admin creation page and create a new administrative account remotely. By gaining admin privileges, the attacker can change the ATM configuration resulting in redirected funds. Public vendor advisories and multiple independent writeups describe the vulnerability as a call to the page used for initial/default installation / first administration user creation; General Bytes has not publicly published the exact endpoint/parameter name. The issue was actively exploited in the wild against cloud-hosted and standalone CAS deployments (scanning exposed CAS instances on ports 7777/443), and publicly acknowledged by the General Bytes in September 2022. |
| By default, the Packet Power Monitoring and Control Web Interface do not
enforce authentication mechanisms. This vulnerability could allow
unauthorized users to access and manipulate monitoring and control
functions. |
| The affected products expose an unauthenticated Telnet-based command line interface that could allow an attacker to modify hardware configurations, manipulate data, or factory reset the device. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166 |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. |
| GALAYOU G2 cameras stream video output via RTSP streams. By default these streams are protected by randomly generated credentials. However these credentials are not required to access the stream. Changing these values does not change camera's behavior.
The vendor did not respond in any way. Only version 11.100001.01.28 was tested, other versions might also be vulnerable. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| An authentication bypass vulnerability exists which allows an unauthenticated attacker to control administrator backup functions, leading to compromise of passwords, secrets, and application session tokens stored by the Unified PAM. |
| In affected versions, vulnerability-lookup did not track or limit failed
One-Time Password (OTP) attempts during Two-Factor Authentication (2FA)
verification. An attacker who already knew or guessed a valid username
and password could submit an arbitrary number of OTP codes without
causing the account to be locked or generating any specific alert for
administrators.
This lack of rate-limiting and lockout on OTP failures significantly
lowers the cost of online brute-force attacks against 2FA codes and
increases the risk of successful account takeover, especially if OTP
entropy is reduced (e.g. short numeric codes, user reuse, or predictable
tokens). Additionally, administrators had no direct visibility into
accounts experiencing repeated 2FA failures, making targeted attacks
harder to detect and investigate.
The patch introduces a persistent failed_otp_attempts counter on user
accounts, locks the user after 5 invalid OTP submissions, resets the
counter on successful verification, and surfaces failed 2FA attempts in
the admin user list. This enforces an account lockout policy for OTP
brute-force attempts and improves monitoring capabilities for suspicious
2FA activity.This issue affects Vulnerability-Lookup: before 2.18.0. |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device. |
| The system exposes several endpoints, typically including "/int/" in their path, that should be restricted to internal services, but are instead publicly accessible without authentication to any host able to reach the application server on port 443/tcp. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| Entrust Instant Financial Issuance (IFI) On Premise software (formerly referred to as CardWizard) versions 5.x, prior to 6.10.5, and prior to 6.11.1 contain an insecure .NET Remoting exposure in the Legacy Remoting Service that is enabled by default. The service registers a TCP remoting channel with SOAP and binary formatters configured at TypeFilterLevel=Full and exposes default ObjectURI endpoints such as logfile.rem, photo.rem, cwPhoto.rem, and reports.rem on a network-reachable remoting port. A remote, unauthenticated attacker who can reach the remoting port can invoke exposed remoting objects to read arbitrary files from the server and coerce outbound authentication, and may achieve arbitrary file write and remote code execution via known .NET Remoting exploitation techniques. This can lead to disclosure of sensitive installation and service-account data and compromise of the affected host. |
| The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents. |