| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability exists in Snap One OVRC cloud where an attacker can impersonate a Hub device and send requests to claim and unclaim devices. The attacker only needs to provide the MAC address of the targeted device and can make a request to unclaim it from its original connection and make a request to claim it. |
| Incorrect access control in the component l_0_0.xml of TP-Link ARCHER-C7 v5 allows attackers to access sensitive information. |
| Multiple FCNT Android devices provide the original security features such as "privacy mode" where arbitrary applications can be set not to be displayed, etc.
Under certain conditions, and when an attacker can directly operate the device which its screen is unlocked by a user, the provided security features' setting pages may be exposed and/or the settings may be altered, without authentication. For example, specific applications in the device configured to be hidden may be displayed and/or activated. |
| An issue in Quectel BC95-CNV V100R001C00SPC051 allows attackers to bypass authentication via a crafted NAS message. |
| An issue in Quectel BG96 BG96MAR02A08M1G allows attackers to bypass authentication via a crafted NAS message. NOTE: this is disputed by the supplier. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, since MODBUS/TCP in the products does not have authentication features. |
| The OTP Integration Kit for PingFederate fails to enforce HTTP method validation and state validation properly. The server advances the authentication state without verifying the OTP, thereby bypassing multi-factor authentication. |
| A vulnerability in Palantir's Aries service allowed unauthenticated access to log viewing and management functionality on Apollo instances using default configuration. The defect resulted in both authentication and authorization checks being bypassed, potentially allowing any network-accessible client to view system logs and perform operations without valid credentials. No evidence of exploitation was identified during the vulnerability window. |
| Quest KACE Systems Management Appliance (SMA) 13.0.x before 13.0.385, 13.1.x before 13.1.81, 13.2.x before 13.2.183, 14.0.x before 14.0.341 (Patch 5), and 14.1.x before 14.1.101 (Patch 4) allows unauthenticated users to replace system licenses through a web interface intended for license renewal. Attackers can exploit this to replace valid licenses with expired or trial licenses, causing denial of service. |
| There is a misconfiguration vulnerability inside the Infotainment ECU manufactured by BOSCH. The vulnerability happens during the startup phase of a specific systemd service, and as a result, the following developer features will be activated: the disabled firewall and the launched SSH server.
First identified on Nissan Leaf ZE1 manufactured in 2020. |
| Insufficient authentication in user account management in Yugabyte Platform allows local network attackers with a compromised user session to change critical security information without re-authentication. An attacker with user session and access to application can modify settings such as password and email without being prompted for the current password, enabling account takeover. |
| Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username |
| A vulnerability was found in Windmill 1.380.0. It has been classified as problematic. Affected is an unknown function of the file backend/windmill-api/src/users.rs of the component HTTP Request Handler. The manipulation leads to improper restriction of excessive authentication attempts. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. Upgrading to version 1.390.1 is able to address this issue. The patch is identified as acfe7786152f036f2476f93ab5536571514fa9e3. It is recommended to upgrade the affected component. |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could
cause exposure of private data when an already generated “logcaptures” archive is accessed
directly by HTTPS. |
| Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2 |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device. |
| Improper access restrictions in HCL BigFix Remote Control Server WebUI (versions 10.1.0.0248 and lower) allow non-admin users to view unauthorized information on certain web pages. |
| Lack of Rate Limiting in Sign-up workflow in Perforce Gliffy prior to version 4.14.0-7 on Gliffy online allows attacker to enumerate valid user emails and potentially DOS the server |
| There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure. |