| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. |
| Use of hard-coded password in the GMS ECM endpoint leading to authentication bypass vulnerability.
This issue affects GMS: 9.3.4 and earlier versions.
|
| Use of hard-coded password issue/vulnerability in SS1 Ver.16.0.0.10 and earlier (Media version:16.0.0a and earlier) allows a remote unauthenticated attacker to view arbitrary files with root privileges. |
| A flaw has been found in Tenda RP3 Pro up to 22.5.7.93. This impacts an unknown function of the file force_upgrade.sh of the component Firmware Update Handler. Executing manipulation of the argument current_force_upgrade_pwd can lead to use of hard-coded password. The attack can only be executed locally. The exploit has been published and may be used. |
| On IROAD v9 devices, the dashcam has hardcoded default credentials ("qwertyuiop") that cannot be changed by the user. This allows an attacker within Wi-Fi range to connect to the device's network to perform sniffing. |
| A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in saltbo zpan up to 1.6.5/1.7.0-beta2. It has been rated as problematic. This issue affects the function NewToken of the file zpan/internal/app/service/token.go of the component JSON Web Token Handler. The manipulation with the input 123 leads to use of hard-coded password. The attack may be initiated remotely. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| A vulnerability has been found in Zytec Dalian Zhuoyun Technology Central Authentication Service 3. Affected by this vulnerability is an unknown functionality of the file /index.php/auth/Ops/git of the component HTTP Header Handler. The manipulation of the argument Authorization leads to use of hard-coded password. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A hard-coded weak password vulnerability has been discovered in all Magic-branded devices from Chinese network equipment manufacturer H3C. The vulnerability stems from the use of a hard-coded weak password for the root account in the /etc/shadow configuration or even the absence of any password at all. Some of these devices have the Telnet service enabled by default, or users can choose to enable the Telnet service in other device management interfaces (e.g. /debug.asp or /debug_telnet.asp). In addition, these devices have related interfaces called Virtual Servers, which can map the devices to the public network, posing the risk of remote attacks. Therefore, attackers can obtain the highest root privileges of the devices through the Telnet service using the weak password hardcoded in the firmware (or without a password), and remote attacks are possible. |
| A vulnerability classified as critical was found in NuCom NC-WR744G 8.5.5 Build 20200530.307. This vulnerability affects unknown code of the component Console Application. The manipulation of the argument CMCCAdmin/useradmin/CUAdmin leads to hard-coded credentials. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. |
| DYMO LabelWriter Print Server through 2.366 contains a backdoor hard-coded password that could allow an attacker to take control. |
| Tenda G1V3.1si V16.01.7.8 Firmware V16.01.7.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. |
| Tenda i24V3.0si V3.0.0.5 Firmware V3.0.0.5 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root. |
| Hardcoded Password Vulnerability have been found in CENTUM. Affected products contain a hardcoded password for the user account (PROG) used for CENTUM Authentication Mode within the system. Under the following conditions, there is a risk that an attacker could log in as the PROG user.
The default permission for the PROG users is S1 permission (equivalent to OFFUSER). Therefore, for properly permission-controlled targets of operation and monitoring, even if an attacker user in as the PROG user, the risk of critical operations or configuration changes being performed is considered low. (If the PROG user's permissions have been changed for any reason, there is a risk that operations or configuration changes may be performed under the modified permissions. The CVSS values below are for the default permissions.)
Additionally, exploiting this vulnerability requires an attacker to already have access to the HIS screen controls. Therefore, an attacker can already operate and monitor at that point, regardless of this vulnerability.
The conditions under which this vulnerability is exploited:
If all of the following conditions are met, the affected products are vulnerable to this vulnerability.
-An attacker obtains the hardcoded password using a certain method.
-The HIS with the affected product installed is configured in CTM authentication mode.
-An attacker must have direct access to the aforementioned HIS or be able to break into it remotely using a certain method and perform screen operations.
The affected products and versions are as follows: CENTUM VP R5.01.00 to R5.04.20, R6.01.00 to R6.12.00 and R7.01.00. |
| A use of hard-coded password vulnerability has been reported to affect Hyper Data Protector. The remote attackers can then exploit the vulnerability to gain unauthorized access.
We have already fixed the vulnerability in the following version:
Hyper Data Protector 2.3.1.455 and later |
| Ksenia Security lares (legacy model) version 1.6 contains a default credentials vulnerability that allows unauthorized attackers to gain administrative access. Attackers can exploit the weak default administrative credentials to obtain full control of the home automation system. |
| LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements. |
| An issue in Automai Director v.25.2.0 allows a remote attacker to escalate privileges and obtain sensitive information via a crafted js file |
| A vulnerability was determined in Tenda F1202 1.2.0.9/1.2.0.14/1.2.0.20. Impacted is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. This manipulation with the input Fireitup causes hard-coded credentials. The attack can only be executed locally. A high degree of complexity is needed for the attack. The exploitability is considered difficult. The exploit has been publicly disclosed and may be utilized. |