| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0644 /var/etc/shadow (aka the /etc/shadow symlink target) permissions. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/hostapd* permissions. |
| Zivif PR115-204-P-RS V2.3.4.2103 web cameras contain a hard-coded cat1029 password for the root user. The SONIX operating system's setup renders this password unchangeable and it can be used to access the device via a TELNET session. |
| EMC ESRS Policy Manager prior to 6.8 contains an undocumented account (OpenDS admin) with a default password. A remote attacker with the knowledge of the default password may login to the system and gain administrator privileges to the local LDAP directory server. |
| A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges. |
| Foscam networked devices use the same hardcoded SSL private key across different customers' installations, which allows remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root"). The attacker can make a user that is connected to the repeater click on a malicious link that will log into the telnet and will infect the device with malicious code. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not). |
| A hard-coded credentials issue was discovered on Mimosa Client Radios before 2.2.3, Mimosa Backhaul Radios before 2.2.3, and Mimosa Access Points before 2.2.3. These devices run Mosquitto, a lightweight message broker, to send information between devices. By using the vendor's hard-coded credentials to connect to the broker on any device (whether it be an AP, Client, or Backhaul model), an attacker can view all the messages being sent between the devices. If an attacker connects to an AP, the AP will leak information about any clients connected to it, including the serial numbers, which can be used to remotely factory reset the clients via a page in their web interface. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. |
| An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |
| Mutiny 7.2.0-10788 suffers from Hardcoded root password. |
| Common encryption key appears to be used across all deployed instances of Serv-U FTP Server. Because of this an encrypted value that is exposed to an attacker can be simply recovered to plaintext. |
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Nokia Fastmile 3tg00118abad52 devices shipped by Optus are shipped with a default hardcoded admin account of admin:Nq+L5st7o This account can be used locally to access the web admin interface. |
| GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. |
| An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |