| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in H3C switch h3c-S1526 allows a remote attacker to obtain sensitive information via the S1526.cfg component. |
| next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| phpgt/Dom provides access to modern DOM APIs. Versions of phpgt/Dom prior to 4.1.8 expose the GITHUB_TOKEN in the Dom workflow run artifact. The ci.yml workflow file uses actions/upload-artifact@v4 to upload the build artifact. This artifact is a zip of the current directory, which includes the automatically generated .git/config file containing the run's GITHUB_TOKEN. Seeing as the artifact can be downloaded prior to the end of the workflow, there is a few seconds where an attacker can extract the token from the artifact and use it with the GitHub API to push malicious code or rewrite release commits in your repository. Any downstream user of the repository may be affected, but the token should only be valid for the duration of the workflow run, limiting the time during which exploitation could occur. Version 4.1.8 fixes the issue. |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| A vulnerability has been found in Coinomi up to 1.7.6. This issue affects some unknown processing. Such manipulation leads to cleartext transmission of sensitive information. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is assessed as difficult. The exploit has been disclosed to the public and may be used. The vendor replied with: "(...) there isn't any security implication associated with your findings." |
| Johan Fagerström, member of the AXIS OS Bug Bounty Program, has found that a O3C feature may expose sensitive traffic between the client (Axis device) and (O3C) server. If O3C is not being used this flaw does not apply.
Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2. |
| A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text. |
| Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. |
| Cleartext transmission of sensitive information in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. |
| Bulwark Webmail is a self-hosted webmail client for Stalwart Mail Server. Prior to version 1.4.10, the GET /api/auth/session endpoint previously included the user's plaintext password in the JSON response. This exposed credentials to browser logs, local caches, and network proxie. This issue has been patched in version 1.4.10. |
| A flaw was found in rhn-proxy. This vulnerability may allow the rhn-proxy to transmit user credentials in clear-text when it accesses RHN Satellite. This could lead to information disclosure, where sensitive authentication details are exposed to unauthorized parties. |
| Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric GENESIS versions 11.02 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.02 and prior allows a local attacker to disclose the SQL Server credentials stored in plaintext within the local SQLite file by exploiting this vulnerability, when the local caching feature using SQLite is enabled and SQL authentication is used for the SQL Server authentication. As a result, the unauthorized attacker could access the SQL Server and disclose, tamper with, or destroy data on the server, potentially cause a denial-of-service (DoS) condition on the system. |
| Cleartext Storage of Sensitive Information in GUI vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric AnalytiX versions 10.97.3 and prior, Mitsubishi Electric GENESIS versions 11.02 and prior, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS versions 11.02 and prior allows a local attacker to disclose the SQL Server credentials displayed in plain text in the GUI of the Hyper Historian Splitter feature by exploiting this vulnerability, when SQL authentication is used for the SQL Server authentication. As a result, the unauthorized attacker could access the SQL Server and disclose, tamper with, or destroy data on the server, potentially cause a denial-of-service (DoS) condition on the system. |
| IBM Maximo Application Suite 9.1, 9.0, 8.11, and 8.10 does not set the secure attribute on authorization tokens or session cookies. Attackers may be able to get the cookie values by sending a http:// link to a user or by planting this link in a site the user goes to. The cookie will be sent to the insecure link and the attacker can then obtain the cookie value by snooping the traffic. |
| The W3 Total Cache plugin for WordPress is vulnerable to Sensitive Information Exposure in versions up to, and including, 2.7.5 via Google OAuth API secrets stored in plaintext in the publicly visible plugin source. This can allow unauthenticated attackers to impersonate W3 Total Cache and gain access to user account information in successful conditions. This would not impact the WordPress users site in any way. |
| ReyeeOS 1.204.1614 contains an unencrypted CWMP communication vulnerability that allows attackers to intercept and manipulate device communication through a man-in-the-middle attack. Attackers can create a fake CWMP server to inject and execute arbitrary commands on Ruijie Reyee Cloud devices by exploiting the unprotected HTTP polling requests. |
| GOM Player 2.3.90.5360 contains a remote code execution vulnerability in its Internet Explorer component that allows attackers to execute arbitrary code through DNS spoofing. Attackers can redirect victims using a malicious URL shortcut and WebDAV technique to run a reverse shell with SMB server interaction. |
| A vulnerability has been found in Meesho Online Shopping App up to 27.3 on Android. Affected is an unknown function of the file /api/endpoint of the component com.meesho.supply. Such manipulation leads to risky cryptographic algorithm. The attack may be performed from remote. The attack requires a high level of complexity. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. |