Search Results (1130 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-2328 1 Juniper 1 Northstar Controller 2025-04-20 N/A
An information leak vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unprivileged, authenticated, user to elevate their permissions through reading unprivileged information stored in the NorthStar controller.
CVE-2017-2329 1 Juniper 1 Northstar Controller 2025-04-20 N/A
An insufficient authentication vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an unprivileged, authenticated, user to execute certain specific unprivileged system files capable of causing widespread denials of system services.
CVE-2017-10618 1 Juniper 1 Junos 2025-04-20 N/A
When the 'bgp-error-tolerance' feature â€" designed to help mitigate remote session resets from malformed path attributes â€" is enabled, a BGP UPDATE containing a specifically crafted set of transitive attributes can cause the RPD routing process to crash and restart. Devices with BGP enabled that do not have 'bgp-error-tolerance' configured are not vulnerable to this issue. Affected releases are Juniper Networks Junos OS 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D45, 14.1X53-D50; 14.2 prior to 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F5-S8, 15.1F6-S7, 15.1R5-S6, 15.1R6-S2, 15.1R7; 15.1X49 prior to 15.1X49-D100; 15.1X53 prior to 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R5; 16.2 prior to 16.2R1-S5, 16.2R2; 17.1 prior to 17.1R1-S3, 17.1R2; 17.2 prior to 17.2R1-S2, 17.2R2; 17.2X75 prior to 17.2X75-D50. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-10615 1 Juniper 17 Ex3200, Ex3300, Ex3300-vc and 14 more 2025-04-20 N/A
A vulnerability in the pluggable authentication module (PAM) of Juniper Networks Junos OS may allow an unauthenticated network based attacker to potentially execute arbitrary code or crash daemons such as telnetd or sshd that make use of PAM. Affected Juniper Networks Junos OS releases are: 14.1 from 14.1R5 prior to 14.1R8-S4, 14.1R9; 14.1X53 prior to 14.1X53-D50 on EX and QFX series; 14.2 from 14.2R3 prior to 14.2R7-S8, 14.2R8; No other Junos OS releases are affected by this issue. No other Juniper Networks products are affected by this issue.
CVE-2017-2334 1 Juniper 1 Northstar Controller 2025-04-20 N/A
An information leak vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a network-based malicious attacker to perform a man-in-the-middle attack, thereby stealing authentic credentials from encrypted paths which are easily decrypted, and subsequently gain complete control of the system.
CVE-2017-10613 1 Juniper 1 Junos 2025-04-20 N/A
A vulnerability in a specific loopback filter action command, processed in a specific logical order of operation, in a running configuration of Juniper Networks Junos OS, allows an attacker with CLI access and the ability to initiate remote sessions to the loopback interface with the defined action, to hang the kernel. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D55; 12.3X48 prior to 12.3X48-D35; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X53 prior to 14.1X53-D40; 14.2 prior to 14.2R4-S9, 14.2R7-S8, 14.2R8; 15.1 prior to 15.1F5-S3, 15.1F6, 15.1R4; 15.1X49 prior to 15.1X49-D60; 15.1X53 prior to 15.1X53-D47; 16.1 prior to 16.1R2. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-2336 1 Juniper 1 Screenos 2025-04-20 N/A
A reflected cross site scripting vulnerability in NetScreen WebUI of Juniper Networks Juniper NetScreen Firewall+VPN running ScreenOS allows a network based attacker to inject HTML/JavaScript content into the management session of other users including the administrator. This enables the attacker to effectively execute commands with the permissions of an administrator. This issue affects Juniper Networks ScreenOS 6.3.0 releases prior to 6.3.0r24 on SSG Series. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-10612 1 Juniper 1 Junos Space 2025-04-20 N/A
A persistent site scripting vulnerability in Juniper Networks Junos Space allows users who can change certain configuration to implant malicious Javascript or HTML which may be used to steal information or perform actions as other Junos Space users or administrators. Affected releases are Juniper Networks Junos Space all versions prior to 17.1R1.
CVE-2017-2323 1 Juniper 1 Northstar Controller 2025-04-20 N/A
A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a malicious attacker crafting packets destined to the device to cause a persistent denial of service to the path computation server service.
CVE-2017-2325 1 Juniper 1 Northstar Controller 2025-04-20 N/A
A buffer overflow vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an authenticated malicious user to cause a buffer overflow leading to a denial of service.
CVE-2017-2327 1 Juniper 1 Northstar Controller 2025-04-20 N/A
A denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow an authenticated malicious user to consume large amounts of system resources leading to a cascading denial of services.
CVE-2017-10611 1 Juniper 15 Ex2200, Ex3300, Junos and 12 more 2025-04-20 N/A
If extended statistics are enabled via 'set chassis extended-statistics', when executing any operation that fetches interface statistics, including but not limited to SNMP GET requests, the pfem process or the FPC may crash and restart. Repeated crashes of PFE processing can result in an extended denial of service condition. This issue only affects the following platforms: (1) EX2200, EX3300, XRE200 (2) MX Series routers with MPC7E/8E/9E PFEs installed, and only if 'extended-statistics' are enabled under the [edit chassis] configuration. Affected releases are Juniper Networks Junos OS 14.1 prior to 14.1R8-S5, 14.1R9 on MX Series; 14.1X53 prior to 14.1X53-D46, 14.1X53-D50 on EX2200, EX3300, XRE200; 14.2 prior to 14.2R7-S9, 14.2R8 on MX Series; 15.1 prior to 15.1F5-S8, 15.1F6-S8, 15.1R5-S3, 15.1R6 on MX Series; 16.1 prior to 16.1R4-S5, 16.1R5, 16.1R6 on MX Series; 16.1X65 prior to 16.1X65-D45 on EX2200, EX3300, XRE200; 16.2 prior to 16.2R2-S1, 16.2R3 on MX Series; 17.1 prior to 17.1R2-S2, 17.1R3 on MX Series; 17.2 prior to 17.2R1-S3, 17.2R2 on MX Series; 17.2X75 prior to 17.2X75-D50 on MX Series; 17.3 prior to 17.3R1-S1, 17.3R2 on MX Series. No other Juniper Networks products or platforms are affected by this issue.
CVE-2017-10607 1 Juniper 1 Junos 2025-04-20 N/A
Juniper Networks Junos OS 16.1R1, and services releases based off of 16.1R1, are vulnerable to the receipt of a crafted BGP Protocol Data Unit (PDU) sent directly to the router, which can cause the RPD routing process to crash and restart. Unlike BGP UPDATEs, which are transitive in nature, this issue can only be triggered by a packet sent directly to the IP address of the router. Repeated crashes of the rpd daemon can result in an extended denial of service condition. This issue only affects devices running Junos OS 16.1R1 and services releases based off of 16.1R1 (e.g. 16.1R1-S1, 16.1R1-S2, 16.1R1-S3). No prior versions of Junos OS are affected by this vulnerability, and this issue was resolved in Junos OS 16.2 prior to 16.2R1. No other Juniper Networks products or platforms are affected by this issue. This issue was found during internal product security testing.
CVE-2017-2333 1 Juniper 1 Northstar Controller 2025-04-20 N/A
A persistent denial of service vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a malicious, network-based, authenticated attacker to consume enough system resources to cause a persistent denial of service by visiting certain specific URLs on the server.
CVE-2017-10605 1 Juniper 14 Junos, Srx100, Srx110 and 11 more 2025-04-20 N/A
On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series.
CVE-2017-2332 1 Juniper 1 Northstar Controller 2025-04-20 N/A
An insufficient authentication vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a malicious, network based, unauthenticated attacker to perform privileged actions to gain complete control over the environment.
CVE-2017-2331 1 Juniper 1 Northstar Controller 2025-04-20 N/A
A firewall bypass vulnerability in Juniper Networks NorthStar Controller Application prior to version 2.1.0 Service Pack 1 may allow a network-based malicious attacker to bypass firewall policies, leading to authentication bypass methods, information disclosure, modification of system files, and denials of service.
CVE-2016-4927 1 Juniper 1 Junos Space 2025-04-20 N/A
Insufficient validation of SSH keys in Junos Space before 15.2R2 allows man-in-the-middle (MITM) type of attacks while a Space device is communicating with managed devices.
CVE-2017-10604 1 Juniper 2 Junos, Srx 2025-04-20 N/A
When the device is configured to perform account lockout with a defined period of time, any unauthenticated user attempting to log in as root with an incorrect password can trigger a lockout of the root account. When an SRX Series device is in cluster mode, and a cluster sync or failover operation occurs, then there will be errors associated with synch or failover while the root account is locked out. Administrators can confirm if the root account is locked out via the following command root@device> show system login lockout user root User Lockout start Lockout end root 1995-01-01 01:00:01 PDT 1995-11-01 01:31:01 PDT Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D65 on SRX series; 12.3X48 prior to 12.3X48-D45 on SRX series; 15.1X49 prior to 15.1X49-D75 on SRX series.
CVE-2017-10601 1 Juniper 1 Junos 2025-04-20 N/A
A specific device configuration can result in a commit failure condition. When this occurs, a user is logged in without being prompted for a password while trying to login through console, ssh, ftp, telnet or su, etc., This issue relies upon a device configuration precondition to occur. Typically, device configurations are the result of a trusted administrative change to the system's running configuration. The following error messages may be seen when this failure occurs: mgd: error: commit failed: (statements constraint check failed) Warning: Commit failed, activating partial configuration. Warning: Edit the router configuration to fix these errors. If the administrative changes are not made that result in such a failure, then this issue is not seen. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.3 prior to 12.3R10, 12.3R11; 12.3X48 prior to 12.3X48-D20; 13.2 prior to 13.2R8; 13.3 prior to 13.3R7; 14.1 prior to 14.1R4-S12, 14.1R5, 14.1R6; 14.1X53 prior to 14.1X53-D30; 14.2 prior to 14.2R4; 15.1 prior to 15.1F2, 15.1F3, 15.1R2.