Search Results (4636 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-34105 1 Flexense 1 Diskboss 2026-04-15 N/A
A stack-based buffer overflow vulnerability exists in the built-in web interface of DiskBoss Enterprise versions 7.4.28, 7.5.12, and 8.2.14. The vulnerability arises from improper bounds checking on the path component of HTTP GET requests. By sending a specially crafted long URI, a remote unauthenticated attacker can trigger a buffer overflow, potentially leading to arbitrary code execution with SYSTEM privileges on vulnerable Windows hosts.
CVE-2025-3621 2026-04-15 9.6 Critical
Vulnerabilities* in ActADUR local server product, developed and maintained by ProTNS, allows Remote Code Inclusion on host systems.  * vulnerabilities: * Improper Neutralization of Special Elements used in a Command ('Command Injection') * Use of Hard-coded Credentials * Improper Authentication * Binding to an Unrestricted IP Address The vulnerability has been rated as critical.This issue affects ActADUR: from v2.0.1.9 before v2.0.2.0., hence updating to version v2.0.2.0. or above is required.
CVE-2025-55037 2026-04-15 N/A
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in TkEasyGUI versions prior to v1.0.22. If this vulnerability is exploited, an arbitrary OS command may be executed by a remote unauthenticated attacker if the settings are configured to construct messages from external sources.
CVE-2025-24032 2026-04-15 8.0 High
PAM-PKCS#11 is a Linux-PAM login module that allows a X.509 certificate based user login. Prior to version 0.6.13, if cert_policy is set to none (the default value), then pam_pkcs11 will only check if the user is capable of logging into the token. An attacker may create a different token with the user's public data (e.g. the user's certificate) and a PIN known to the attacker. If no signature with the private key is required, then the attacker may now login as user with that created token. The default to *not* check the private key's signature has been changed with commit commi6638576892b59a99389043c90a1e7dd4d783b921, so that all versions starting with pam_pkcs11-0.6.0 should be affected. As a workaround, in `pam_pkcs11.conf`, set at least `cert_policy = signature;`.
CVE-2025-46275 2026-04-15 9.8 Critical
WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.
CVE-2025-2567 2026-04-15 9.8 Critical
An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation.
CVE-2025-34089 2026-04-15 N/A
An unauthenticated remote code execution vulnerability exists in Remote for Mac, a macOS remote control utility developed by Aexol Studio, in versions up to and including 2025.7. When the application is configured with authentication disabled (i.e., the "Allow unknown devices" option is enabled), the /api/executeScript endpoint is exposed without access control. This allows unauthenticated remote attackers to inject arbitrary AppleScript payloads via the X-Script HTTP header, resulting in code execution using do shell script. Successful exploitation grants attackers the ability to run arbitrary commands on the macOS host with the privileges of the Remote for Mac background process.
CVE-2025-36751 1 Growatt 2 Mic3300tl-x, Shinelan-x 2026-04-15 N/A
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
CVE-2025-22273 1 Cyberark 1 Endpoint Privilege Manager 2026-04-15 N/A
Application does not limit the number or frequency of user interactions, such as the number of incoming requests. At the "/EPMUI/VfManager.asmx/ChangePassword" endpoint it is possible to perform a brute force attack on the current password in use. This issue affects CyberArk Endpoint Privilege Manager in SaaS version 24.7.1. The status of other versions is unknown. After multiple attempts to contact the vendor we did not receive any answer.
CVE-2024-5539 1 Carrier 2 Automatedlogic Webctrl, I-vu 2026-04-15 N/A
The Access Control Bypass vulnerability found in ALC WebCTRL and Carrier i-Vu in versions up to and including 8.5 allows a malicious actor to bypass intended access restrictions and expose sensitive information via the web based building automation server.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2020-37052 1 Ubiquiti 1 Aircontrol 2026-04-15 9.8 Critical
AirControl 1.4.2 contains a pre-authentication remote code execution vulnerability that allows unauthenticated attackers to execute arbitrary system commands through malicious Java expression injection. Attackers can exploit the /.seam endpoint by crafting a specially constructed URL with embedded Java expressions to run commands with the application's system privileges.
CVE-2020-37027 1 Midgetspy 1 Sickbeard 2026-04-15 9.8 Critical
Sickbeard alpha contains a remote command injection vulnerability that allows unauthenticated attackers to execute arbitrary commands through the extra scripts configuration. Attackers can set malicious commands in the extra scripts field and trigger processing to execute remote code on the vulnerable Sickbeard installation.
CVE-2025-8890 1 Sdmc 1 Ne6037 2026-04-15 N/A
Firmware in SDMC NE6037 routers prior to version 7.1.12.2.44 has a network diagnostics tool vulnerable to a shell command injection attacks. In order to exploit this vulnerability, an attacker has to log in to the router's administrative portal, which by default is reachable only via LAN ports.
CVE-2025-30519 1 Doverfuelingsolutions 1 Progauge Maglink Lx Console 2026-04-15 9.8 Critical
Dover Fueling Solutions ProGauge MagLink LX4 Devices have default root credentials that cannot be changed through standard administrative means. An attacker with network access to the device can gain administrative access to the system.
CVE-2025-8769 1 Megasys 1 Telenium Online Web Application 2026-04-15 9.8 Critical
Telenium Online Web Application is vulnerable due to a Perl script that is called to load the login page. Due to improper input validation, an attacker can inject arbitrary Perl code through a crafted HTTP request, leading to remote code execution on the server.