Search Results (4637 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-52320 1 Planet Technology Corp 1 Wgs-804hpt Firmware 2026-04-15 9.8 Critical
The affected product is vulnerable to a command injection. An unauthenticated attacker could send commands through a malicious HTTP request which could result in remote code execution.
CVE-2025-27720 2026-04-15 7.4 High
The Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials.
CVE-2024-56333 2026-04-15 N/A
Onyxia is a web app that aims at being the glue between multiple open source backend technologies to provide a state of art working environment for data scientists. This critical vulnerability allows authenticated users to remotely execute code within the Onyxia-API, leading to potential consequences such as unauthorized access to other user environments and denial of service attacks. This issue has been patched in api versions 4.2.0, 3.1.1, and 2.8.2. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-5023 1 Netflix 1 Consoleme 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Netflix ConsoleMe allows Command Injection.This issue affects ConsoleMe: before 1.4.0.
CVE-2024-4999 2026-04-15 N/A
A vulnerability in the web-based management interface of multiple Ligowave devices could allow an authenticated remote attacker to execute arbitrary commands with elevated privileges.This issue affects UNITY: through 6.95-2; PRO: through 6.95-1.Rt3883; MIMO: through 6.95-1.Rt2880; APC Propeller: through 2-5.95-4.Rt3352.
CVE-2024-4996 2026-04-15 9.8 Critical
Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0.
CVE-2025-34147 1 Shenzhen Aitemi 1 M300 Wifi Repeater 2026-04-15 N/A
An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02). When configuring the device in Extender mode via its captive portal, the extap2g SSID field is inserted unescaped into a reboot-time shell script. This allows remote attackers within Wi-Fi range to inject arbitrary shell commands that execute as root during device reboot, leading to full system compromise.
CVE-2024-49397 1 Elvaco 1 Cme3100 Firmware 2026-04-15 N/A
The affected product is vulnerable to a cross-site scripting attack which may allow an attacker to bypass authentication and takeover admin accounts.
CVE-2019-25322 1 Heatmiser 1 Heatmiser Netmonitor 2026-04-15 7.5 High
Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields.
CVE-2024-45369 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 8.1 High
The web application uses a weak authentication mechanism to verify that a request is coming from an authenticated and authorized resource.
CVE-2024-45367 1 Optigo 1 Ons-s8 Firmware 2026-04-15 9.1 Critical
The web server for ONS-S8 - Spectra Aggregation Switch includes an incomplete authentication process, which can lead to an attacker authenticating without a password.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-64125 1 Nuvation Energy 1 Ncloud Vpn Service 2026-04-15 N/A
A vulnerability in Nuvation Energy nCloud VPN Service allowed Network Boundary Bridging.This issue affected the nCloud VPN Service and was fixed on 2025-12-1 (December, 2025). End users do not have to take any action to mitigate the issue.
CVE-2025-7503 2026-04-15 N/A
An OEM IP camera manufactured by Shenzhen Liandian Communication Technology LTD exposes a Telnet service (port 23) with undocumented, default credentials. The Telnet service is enabled by default and is not disclosed or configurable via the device’s web interface or user manual. An attacker with network access can authenticate using default credentials and gain root-level shell access to the device. The affected firmware version is AppFHE1_V1.0.6.0 (Kernel: KerFHE1_PTZ_WIFI_V3.1.1, Hardware: HwFHE1_WF6_PTZ_WIFI_20201218). No official fix or firmware update is available, and the vendor could not be contacted. This vulnerability allows for remote code execution and privilege escalation.
CVE-2024-41798 1 Siemens 1 Sentron Pac3200 2026-04-15 9.8 Critical
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
CVE-2024-37998 2026-04-15 9.8 Critical
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto login is enabled. This could allow an unauthorized attacker to obtain administrative access of the affected applications.
CVE-2024-38492 1 Broadcom 1 Symantec Privileged Access Management 2026-04-15 N/A
This vulnerability allows an unauthenticated attacker to achieve remote command execution on the affected PAM system by uploading a specially crafted PAM upgrade file.
CVE-2017-20203 1 Netsarang 5 Xftp, Xlpd, Xmanager and 2 more 2026-04-15 N/A
NetSarang Xmanager Enterprise 5.0 Build 1232, Xmanager 5.0 Build 1045, Xshell 5.0 Build 1322, Xftp 5.0 Build 1218, and Xlpd 5.0 Build 1220 contain a malicious nssock2.dll that implements a multi-stage, DNS-based backdoor. The dormant library contacts a C2 DNS server via a specially crafted TXT record for a month‑generated domain. After receiving a decryption key, it then downloads and executes arbitrary code, creates an encrypted virtual file system (VFS) in the registry, and grants the attacker full remote code execution, data exfiltration, and persistence. NetSarang released builds for each product line that remediated the compromise: Xmanager Enterprise Build 1236, Xmanager Build 1049, Xshell Build 1326, Xftp Build 1222, and Xlpd Build 1224. Kaspersky Lab identified an instance of exploitation in the wild in August 2017.
CVE-2025-40585 1 Siemens 2 Energy Services, G5dfr 2026-04-15 9.9 Critical
A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contain default credentials. This could allow an attacker to gain control of G5DFR component and tamper with outputs from the device.