| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A hardcoded privileged ID within Lumisxp v15.0.x to v16.1.x allows attackers to bypass authentication and access internal pages and other sensitive information. |
| Use of hard-coded credentials issue exists in Ricoh Streamline NX PC Client ver.3.7.2 and earlier. If this vulnerability is exploited, an attacker may obtain LocalSystem Account of the PC where the product is installed. As a result, unintended operations may be performed on the PC. |
| The Versa Director uses PostgreSQL (Postgres) to store operational and configuration data. It is also needed for High Availability function of the Versa Director. The default configuration has a common password across all instances of Versa Director. By default, Versa Director configures Postgres to listen on all network interfaces. This combination allows an unauthenticated attacker to access and administer the database or read local filesystem contents to escalate privileges on the system.
Exploitation Status:
Versa Networks is not aware of this exploitation in any production systems. A proof of concept exists in the lab environment.
Workarounds or Mitigation:
Starting with the latest 22.1.4 version of Versa Director, the software will automatically restrict access to the Postgres and HA ports to only the local and peer Versa Directors. For older releases, Versa recommends performing manual hardening of HA ports. Please refer to the following link for the steps https://docs.versa-networks.com/Solutions/System_Hardening/Perform_Manual_Hardening_for_Versa_Director#Secure_HA_Ports
This vulnerability is not exploitable on Versa Directors if published Firewall guidelines are implemented. We have validated that no Versa-hosted head ends have been affected by this vulnerability. All Versa-hosted head ends are patched and hardened.
Please contact Versa Technical Support or Versa account team for any further assistance.
Software Download Links:
22.1.4: https://support.versa-networks.com/support/solutions/articles/23000026708-release-22-1-4 |
| The configuration file is encrypted with a static key derived from a
static five-character password which allows an attacker to decrypt this
file. The application hashes this five-character password with
the outdated and broken MD5 algorithm (no salt) and uses the first five
bytes as the key for RC4. The configuration file is then encrypted with
these parameters. |
| AL-KO Robolinho Update Software has hard-coded AWS Access and Secret keys that allow anyone to access AL-KO's AWS bucket. Using the keys directly might give the attacker greater access than the app itself. Key grants AT LEAST read access to some of the objects in bucket.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only versions 8.0.21.0610 and 8.0.22.0524 were tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| A vulnerability was identified in MEPIS RM, an industrial
software product developed by Metronik. The application contained a hardcoded
cryptographic key within the Mx.Web.ComponentModel.dll component. When the
option to store domain passwords was enabled, this key was used to encrypt user
passwords before storing them in the application’s database. An attacker with
sufficient privileges to access the database could extract the encrypted
passwords, decrypt them using the embedded key, and gain unauthorized access to
the associated ICS/OT environment. |
| The Civi - Job Board & Freelance Marketplace WordPress Theme plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 2.1.4 via hard-coded credentials. This makes it possible for unauthenticated attackers to extract sensitive data including LinkedIn client and secret keys. |
| A hardcoded credential vulnerability exists in the Blue Angel Software Suite deployed on embedded Linux systems. The application contains multiple known default and hardcoded user accounts that are not disclosed in public documentation. These accounts allow unauthenticated or low-privilege attackers to gain administrative access to the device’s web interface. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-26 UTC. |
| GarrettCom Magnum 6K and 10K managed switches contain an authentication bypass vulnerability that allows unauthenticated attackers to gain unauthorized access by exploiting a hardcoded string in the authentication mechanism. Attackers can bypass login controls to access administrative functions and sensitive switch configuration without valid credentials. |
| Storage credentials are hardcoded in the mobile app and device firmware. These credentials do not adequately limit end user permissions and do not expire within a reasonable amount of time. This vulnerability may grant unauthorized access to production storage containers. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. The application uses a hard-coded decryption password to protect sensitive user information. |
| In Ruckus Network Director (RND) < 4.5.0.54, the OVA appliance contains hardcoded credentials for the ruckus PostgreSQL database user. In the default configuration, the PostgreSQL service is accessible over the network on TCP port 5432. An attacker can use the hardcoded credentials to authenticate remotely, gaining superuser access to the database. This allows creation of administrative users for the web interface, extraction of password hashes, and execution of arbitrary OS commands. |
| A hardcoded cryptographic key within the configuration mechanism on TP-Link Archer NX200, NX210, NX500 and NX600 enables decryption and re-encryption of device configuration data. An authenticated attacker may decrypt configuration files, modify them, and re-encrypt them, affecting the confidentiality and integrity of device configuration data. |
| Use of Hard-coded Credentials vulnerability in Microchip Time Provider 4100 allows Malicious Manual Software Update.This issue affects Time Provider 4100: before 2.5.0. |
| A Use of Hard-coded Credentials vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to disclose sensitive information and take over accounts. |
| IBM Concert 1.0.0 through 2.2.0 contains hard-coded credentials that could be obtained by a local user. |
| HCL Aftermarket DPC is affected by Hardcoded Sensitive Data which allows attacker to gain access to the source code or if it is stored in insecure repositories, they can easily retrieve these hardcoded secrets. |
| HCL Aftermarket DPC is affected by SQL Injection which allows attacker to exploit this vulnerability to retrieve sensitive information from the database. |
| A use of hard-coded credentials vulnerability has been reported to affect QuNetSwitch. The remote attackers can then exploit the vulnerability to gain unauthorized access.
We have already fixed the vulnerability in the following version:
QuNetSwitch 2.0.5.0906 and later |
| Use of hard coded credentials in GoHarbor Harbor version 2.15.0 and below, allows attackers to use the default password and gain access to the web UI. |