| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| ComfyUI-Bmad-Nodes is vulnerable to Code Injection. The issue stems from a validation bypass in the BuildColorRangeHSVAdvanced, FilterContour and FindContour custom nodes. In the entrypoint function to each node, there’s a call to eval which can be triggered by generating a workflow that injects a crafted string into the node. This can result in executing arbitrary code on the server. |
| An OS command injection vulnerability exists in sar2html version 3.2.2 and prior via the plot parameter in index.php. The application fails to sanitize user-supplied input before using it in a system-level context. Remote, unauthenticated attackers can inject shell commands by appending them to the plot parameter (e.g., ?plot=;id) in a crafted GET request. The output of the command is displayed in the application's interface after interacting with the host selection UI. Successful exploitation leads to arbitrary command execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| In the moPS App through 1.8.618, all users can access administrative API endpoints without additional authentication, resulting in unrestricted read and write access, as demonstrated by /api/v1/users/resetpassword. |
| An unrestricted upload of file with dangerous type in Automated Logic WebCTRL 7.0 could allow an unauthenticated user to perform remote command execution via a crafted HTTP POST request which could lead to uploading a malicious file. |
| Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username |
| Volt is an elegantly crafted functional API for Livewire. Malicious, user-crafted request payloads could potentially lead to remote code execution within Volt components. This vulnerability is fixed in 1.7.0. |
| Certain models of Industrial Cellular Gateway developed by Planet Technology have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to manipulate the device via a specific functionality. |
| CL4/6NX Plus and CL4/6NX-J Plus (Japan model) with the firmware versions prior to 1.15.5-r1 allow crafted dangerous files to be uploaded. An arbitrary Lua script may be executed on the system with the root privilege. |
| Improper Link Resolution Before File Access ('Link Following') vulnerability in yrutschle sslh.This issue affects sslh: before 2.2.2. |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges. |
| Prism Central versions prior to 2024.3.1 are vulnerable to a stored cross-site scripting attack via the Events component, allowing an attacker to hijack a victim user’s session and perform actions in their security context. |
| Better Auth is an authentication and authorization library for TypeScript. In versions prior to 1.3.26, unauthenticated attackers can create or modify API keys for any user by passing that user's id in the request body to the `api/auth/api-key/create` route. `session?.user ?? (authRequired ? null : { id: ctx.body.userId })`. When no session exists but `userId` is present in the request body, `authRequired` becomes false and the user object is set to the attacker-controlled ID. Server-only field validation only executes when `authRequired` is true (lines 280-295), allowing attackers to set privileged fields. No additional authentication occurs before the database operation, so the malicious payload is accepted. The same pattern exists in the update endpoint. This is a critical authentication bypass enabling full an unauthenticated attacker can generate an API key for any user and immediately gain complete authenticated access. This allows the attacker to perform any action as the victim user using the api key, potentially compromise the user data and the application depending on the victim's privileges. Version 1.3.26 contains a patch for the issue. |
| Hyperbridge is a hyper-scalable coprocessor for verifiable, cross-chain interoperability. A critical vulnerability was discovered in the ismp-grandpa crate, that allowed a malicious prover easily convince the verifier of the finality of arbitrary headers. This could be used to steal funds or compromise other kinds of cross-chain applications. This vulnerability is fixed in 15.0.1. |
| A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user. |
| When uploading organism or sequence data via the web interface,
GMOD Apollo
will unzip and inspect the files and will not check for path
traversal in supported archive types. |
| The Survision LPR Camera system does not enforce password protection by default. This allows access to the configuration wizard immediately without a login prompt or credentials check. |
| H3C Intelligent Management Center (IMC) versions up to and including E0632H07 contains a remote command execution vulnerability in the /byod/index.xhtml endpoint. Improper handling of JSF ViewState allows unauthenticated attackers to craft POST requests with forged javax.faces.ViewState parameters, potentially leading to arbitrary command execution. This flaw does not require authentication and may be exploited without session cookies. An affected version range is undefined. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-08-28 UTC. |
| QiAnXin TianQing Management Center versions up to and including 6.7.0.4130 contain a path traversal vulnerability in the rptsvr component that allows unauthenticated attackers to upload files to arbitrary locations on the server. The /rptsvr/upload endpoint fails to sanitize the filename parameter in multipart form-data requests, enabling path traversal. This allows attackers to place executable files in web-accessible directories, potentially leading to remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-08-23 UTC. |
| A command injection vulnerability in Dahua EIMS versions prior to 2240008 allows unauthenticated remote attackers to execute arbitrary system commands via the capture_handle.action interface. The flaw stems from improper input validation in the captureCommand parameter, which is processed without sanitization or authentication. By sending crafted HTTP requests, attackers can inject OS-level commands that are executed on the server, leading to full system compromise. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-04-06 UTC. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |