Search Results (7800 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-48978 1 Ui 1 Edgeswitch 2026-04-15 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network. Affected Products: EdgeMAX EdgeSwitch (Version 1.11.0 and earlier) Mitigation: Update the EdgeMAX EdgeSwitch to Version 1.11.1 or later.
CVE-2023-49565 1 Nokia 2 Cbis, Ncs 2026-04-15 8.4 High
The cbis_manager Podman container is vulnerable to remote command execution via the /api/plugins endpoint. Improper sanitization of the HTTP Headers X-FILENAME, X-PAGE, and X-FIELD allows for command injection. These headers are directly utilized within the subprocess.Popen Python function without adequate validation, enabling a remote attacker to execute arbitrary commands on the underlying system by crafting malicious header values within an HTTP request to the affected endpoint. The web service executes with root privileges within the container environment, the demonstrated remote code execution permits an attacker to acquire elevated privileges for the command execution. Restricting access to the management network with an external firewall can partially mitigate this risk.
CVE-2025-27212 2 Ubiquiti, Ui 5 Unifi Access Points, Unifi Os, Intercom and 2 more 2026-04-15 9.8 Critical
An Improper Input Validation in certain UniFi Access devices could allow a Command Injection by a malicious actor with access to UniFi Access management network. Affected Products: UniFi Access Reader Pro (Version 2.14.21 and earlier) UniFi Access G2 Reader Pro (Version 1.10.32 and earlier) UniFi Access G3 Reader Pro (Version 1.10.30 and earlier) UniFi Access Intercom (Version 1.7.28 and earlier) UniFi Access G3 Intercom (Version 1.7.29 and earlier) UniFi Access Intercom Viewer (Version 1.3.20 and earlier) Mitigation: Update UniFi Access Reader Pro Version 2.15.9 or later Update UniFi Access G2 Reader Pro Version 1.11.23 or later Update UniFi Access G3 Reader Pro Version 1.11.22 or later Update UniFi Access Intercom Version 1.8.22 or later Update UniFi Access G3 Intercom Version 1.8.22 or later Update UniFi Access Intercom Viewer Version 1.4.39 or later
CVE-2025-22962 2026-04-15 7.2 High
A critical remote code execution (RCE) vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters when debugging mode is enabled. An attacker with a valid session ID (sess_id) can send specially crafted POST requests to the /json endpoint, enabling arbitrary command execution on the underlying system. This vulnerability can lead to full system compromise, including unauthorized access, privilege escalation, and potentially full device takeover.
CVE-2025-24317 2026-04-15 N/A
Allocation of resources without limits or throttling issue exists in HMI ViewJet C-more series and HMI GC-A2 series, which may allow a remote unauthenticated attacker to cause a denial-of-service (DoS) condition.
CVE-2025-32025 2026-04-15 N/A
bep/imagemeta is a Go library for reading EXIF, IPTC and XMP image meta data from JPEG, TIFF, PNG, and WebP files. The buffer created for parsing metadata for PNG and WebP images was only bounded by their input data type, which could lead to potentially large memory allocation, and unreasonably high for image metadata. Before v0.11.0, If you didn't trust the input images, this could be abused to construct denial-of-service attacks. v0.11.0 added a 10 MB upper limit.
CVE-2025-32032 2026-04-15 7.5 High
The Apollo Router Core is a configurable, high-performance graph router written in Rust to run a federated supergraph that uses Apollo Federation 2. A vulnerability in Apollo Router allowed queries with deeply nested and reused named fragments to be prohibitively expensive to query plan, specifically due to internal optimizations being frequently bypassed. The query planner includes an optimization that significantly speeds up planning for applicable GraphQL selections. However, queries with deeply nested and reused named fragments can generate many selections where this optimization does not apply, leading to significantly longer planning times. Because the query planner does not enforce a timeout, a small number of such queries can exhaust router's thread pool, rendering it inoperable. This could lead to excessive resource consumption and denial of service. This has been remediated in apollo-router versions 1.61.2 and 2.1.1.
CVE-2025-32034 2026-04-15 7.5 High
The Apollo Router Core is a configurable, high-performance graph router written in Rust to run a federated supergraph that uses Apollo Federation 2. Prior to 1.61.2 and 2.1.1, a vulnerability in Apollo Router allowed queries with deeply nested and reused named fragments to be prohibitively expensive to query plan, specifically during named fragment expansion. Named fragments were being expanded once per fragment spread during query planning, leading to exponential resource usage when deeply nested and reused fragments were involved. This could lead to excessive resource consumption and denial of service. This has been remediated in apollo-router versions 1.61.2 and 2.1.1.
CVE-2023-1000 2026-04-15 6.3 Medium
A vulnerability was found in cyanomiko dcnnt-py up to 0.9.0. It has been classified as critical. Affected is the function main of the file dcnnt/plugins/notifications.py of the component Notification Handler. The manipulation leads to command injection. It is possible to launch the attack remotely. Upgrading to version 0.9.1 is able to address this issue. The patch is identified as b4021d784a97e25151a5353aa763a741e9a148f5. It is recommended to upgrade the affected component. VDB-262230 is the identifier assigned to this vulnerability.
CVE-2024-6333 1 Xerox 4 Altalink Firmware, Versalink Firmware, Workcentre Firmware and 1 more 2026-04-15 7.2 High
Authenticated Remote Code Execution in Altalink, Versalink & WorkCentre Products.
CVE-2024-6509 2026-04-15 6.5 Medium
Marinus Pfund, member of the AXIS OS Bug Bounty Program, has found the VAPIX API alwaysmulti.cgi was vulnerable for file globbing which could lead to resource exhaustion of the Axis device. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution.
CVE-2025-43948 2026-04-15 7.3 High
Codemers KLIMS 1.6.DEV allows Python code injection. A user can provide Python code as an input value for a parameter or qualifier (such as for sorting), which will get executed on the server side.
CVE-2025-44003 2026-04-15 4.3 Medium
Missing Release of Resource after Effective Lifetime (CWE-772) in the Gallagher T-Series Reader allows an attacker with physical access to the reader to perform a limited denial of service when 125 kHz Card Technology is enabled. This issue affects T-Series Readers: 9.20 prior to vCR9.20.250213a (distributed in 9.20.1827 (MR2)), 9.10 prior to vCR9.10.250213a (distributed in 9.10.2692(MR5)), 9.00 prior to vCR9.00.250619a (distributed in  vEL9.00.3371 (MR7)),  all versions of 8.90 and prior.
CVE-2025-44023 1 Dlink 2 Dns-320, Dns-320lw 2026-04-15 6.5 Medium
An issue in dlink DNS-320 v.1.00 and DNS-320LW v.1.01.0914.20212 allows an attacker to execute arbitrary via the account_mgr.cgi->cgi_chg_admin_pw components.
CVE-2025-52337 2026-04-15 6.5 Medium
An authenticated arbitrary file upload vulnerability in the Content Explorer feature of LogicData eCommerce Framework v5.0.9.7000 allows attackers to execute arbitrary code via uploading a crafted file.
CVE-2025-4653 2026-04-15 N/A
Improper Neutralization of Special Elements in the backup name field may allow OS command injection. This issue affects Pandora ITSM 5.0.105.
CVE-2025-2730 2026-04-15 8 High
A vulnerability was found in H3C Magic NX15, Magic NX30 Pro, Magic NX400, Magic R3010 and Magic BE18000 up to V100R014. It has been classified as critical. Affected is an unknown function of the file /api/wizard/getssidname of the component HTTP POST Request Handler. The manipulation leads to command injection. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component.
CVE-2025-27211 1 Ui 1 Edgeswitch 2026-04-15 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.
CVE-2025-52687 2026-04-15 2.4 Low
Successful exploitation of the vulnerability could allow an attacker with administrator credentials for the access point to inject malicious JavaScript into the payload of web traffics, potentially leading to session hijacking and denial-of-service (DoS).
CVE-2025-52688 2026-04-15 9.8 Critical
Successful exploitation of the vulnerability could allow an attacker to inject commands with root privileges on the access point, potentially leading to the loss of confidentiality, integrity, availability, and full control of the access point.