| Smart Parking Management System from Honding Technology has an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to access a specific page and obtain plaintext administrator credentials. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of validation in the langGet parameter in the adm.cgi endpoint, the malicious attacker can execute system shell commands.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGEDCOM ROX RX1400 (All versions < V2.16.5), RUGGEDCOM ROX RX1500 (All versions < V2.16.5), RUGGEDCOM ROX RX1501 (All versions < V2.16.5), RUGGEDCOM ROX RX1510 (All versions < V2.16.5), RUGGEDCOM ROX RX1511 (All versions < V2.16.5), RUGGEDCOM ROX RX1512 (All versions < V2.16.5), RUGGEDCOM ROX RX1524 (All versions < V2.16.5), RUGGEDCOM ROX RX1536 (All versions < V2.16.5), RUGGEDCOM ROX RX5000 (All versions < V2.16.5). The 'ping' tool in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated remote attacker to execute arbitrary code with root privileges. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| A vulnerability in Longwatch devices allows unauthenticated HTTP GET requests to execute arbitrary code via an exposed endpoint, due to the absence of code signing and execution controls. Exploitation results in SYSTEM-level privileges. |
| ComfyUI-Bmad-Nodes is vulnerable to Code Injection. The issue stems from a validation bypass in the BuildColorRangeHSVAdvanced, FilterContour and FindContour custom nodes. In the entrypoint function to each node, there’s a call to eval which can be triggered by generating a workflow that injects a crafted string into the node. This can result in executing arbitrary code on the server. |
| An OS command injection vulnerability exists in sar2html version 3.2.2 and prior via the plot parameter in index.php. The application fails to sanitize user-supplied input before using it in a system-level context. Remote, unauthenticated attackers can inject shell commands by appending them to the plot parameter (e.g., ?plot=;id) in a crafted GET request. The output of the command is displayed in the application's interface after interacting with the host selection UI. Successful exploitation leads to arbitrary command execution on the underlying system. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created
over the web interface HTTP when enabled. HTTP is disabled by default. |
| Improper Input validation leads to XSS or Cross-site Scripting vulnerability in OpenText Advanced Authentication. This issue affects Advanced Authentication versions before 6.5. |
| The affected product does not limit the number of attempts for inputting
the correct PIN for a registered product, which may allow an attacker
to gain unauthorized access using brute-force methods if they possess a
valid device serial number. The API provides clear feedback when the
correct PIN is entered. This vulnerability was patched in a server-side
update on April 6, 2025. |
| Cap Collectif is an online decision making platform that integrates several tools. Before commit 812f2a7d271b76deab1175bdaf2be0b8102dd198, the `DebateAlternateArgumentsResolver` deserializes a `Cursor`, allowing any classes and which can be controlled by unauthenticated user. Exploitation of this vulnerability can lead to Remote Code Execution. The vulnerability is fixed in commit 812f2a7d271b76deab1175bdaf2be0b8102dd198. |
| Various Ruijie Gateway EG and NBR models firmware versions 11.1(6)B9P1 < 11.9(4)B12P1 contain a code execution vulnerability in the EWEB management system that can be abused via front-end functionality. Attackers can exploit front-end code when features such as guest authentication, local server authentication, or screen mirroring are enabled to gain access or execute commands on affected devices. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-02-05 UTC. |
| In the moPS App through 1.8.618, all users can access administrative API endpoints without additional authentication, resulting in unrestricted read and write access, as demonstrated by /api/v1/users/resetpassword. |
| A vulnerability was found in WAVLINK QUANTUM D2G, QUANTUM D3G, WL-WN530G3A, WL-WN530HG3, WL-WN532A3 and WL-WN576K1 up to V1410_240222 and classified as critical. Affected by this issue is the function sys_login of the file /cgi-bin/login.cgi of the component HTTP POST Request Handler. The manipulation of the argument login_page leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| An unrestricted upload of file with dangerous type in Automated Logic WebCTRL 7.0 could allow an unauthenticated user to perform remote command execution via a crafted HTTP POST request which could lead to uploading a malicious file. |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in SkyBridge BASIC MB-A130 Ver.1.5.8 and earlier. If exploited, a remote unauthenticated attacker may execute arbitrary OS commands with root privileges. |
| Improper Link Resolution Before File Access ('Link Following') vulnerability in yrutschle sslh.This issue affects sslh: before 2.2.2. |
| Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username |
| Volt is an elegantly crafted functional API for Livewire. Malicious, user-crafted request payloads could potentially lead to remote code execution within Volt components. This vulnerability is fixed in 1.7.0. |