| Improper Authentication (CWE-287) in the PAM configuration in Loytec LIP-ME201C, L-INX, L-GATE, L-ROC, L-IOB, L-DALI, L-VIS and L-PAD through 8.4.16 on LINX-A64 allows a local attacker to authenticate as a uid=0 account without a password and obtain a root shell via an `/etc/passwd` entry with an empty password field. |
| HCL MyCloud was affected with Weak Password Policy. It may increase the risk of account compromise through brute-force or credential-based attacks. |
| Hikvision Streaming Media Management Server v2.3.5 uses default credentials that allow remote attackers to authenticate and access restricted functionality. After authenticating with these credentials, an attacker can exploit an arbitrary file read vulnerability in the /systemLog/downFile.php endpoint via directory traversal in the fileName parameter. This exploit chain can enable unauthorized access to sensitive system files. |
| KTM System e-BOK enforces a maximum password length of six numeric digits and does not permit the use of any alphabetic, special, or extended characters.
This issue was fixed in the patch published in June 2026. |
| A weakness has been identified in Tenda AC15 15.03.05.19. The impacted element is an unknown function of the file /etc_ro/smb.conf of the component Samba. Executing a manipulation can lead to weak password requirements. The attack is only possible within the local network. A high complexity level is associated with this attack. The exploitability is regarded as difficult. The exploit has been made available to the public and could be used for attacks. |
| IBM Operations Analytics - Log Analysis 1.3.5.0, 1.3.5.1, 1.3.5.2, 1.3.5.3, 1.3.6.0, 1.3.6.1, 1.3.7.0, 1.3.7.1, 1.3.7.2, and 1.3.8.0, 1.3.8.1, 1.3.8.2, 1.3.8.3, 1.3.8.4 IBM SmartCloud Analytics - Log Analysis does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. |
| A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password. |
| A vulnerability was determined in Besen BS20 EV Charging Station up to 20260426. This impacts an unknown function of the component Bluetooth Low Energy Handler. Executing a manipulation can lead to weak password requirements. The attack needs to be done within the local network. This attack is characterized by high complexity. The exploitability is said to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026." |
| This vulnerability exists in Quantum Networks router due to lack of enforcement of strong password policies in the web-based management interface. An attacker on the same network could exploit this vulnerability by performing password guessing or brute-force attacks against user accounts, leading to unauthorized access to the targeted device. |
| HCL AION version 2 is affected by a Weak Password Policy vulnerability. This can allow the use of easily guessable passwords, potentially resulting in unauthorized access |
| An attacker with network access to the PLC is able to brute force discover passwords to gain unauthorized access to systems and services. The limited password complexity and no password input limiters makes brute force password enumeration possible. |
| The web management interface of the device allows the administrator
username and password to be set to blank values. Once applied, the
device permits authentication with empty credentials over the web
management interface and Telnet service. This effectively disables
authentication across all critical management channels, allowing any
network-adjacent attacker to gain full administrative control without
credentials. |
| A weakness has been identified in Beetel 777VR1 up to 01.00.09/01.00.09_55. This vulnerability affects unknown code of the component UART Interface. Executing a manipulation can lead to weak password requirements. The physical device can be targeted for the attack. The attack requires a high level of complexity. It is stated that the exploitability is difficult. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way. |
| Vikunja is an open-source self-hosted task management platform. Prior to version 2.0.0, the application allows users to set weak passwords (e.g., 1234, password) without enforcing minimum strength requirements. Additionally, active sessions remain valid after a user changes their password. An attacker who compromises an account (via brute-force or credential stuffing) can maintain persistent access even after the victim resets their password. Version 2.0.0 contains a fix. |
| Users who were required to change their password could still access system information before changing their password |
| A vulnerability was detected in iteachyou Dreamer CMS up to 4.1.3.2. This issue affects some unknown processing of the file /admin/user/updatePwd. Performing manipulation results in weak password requirements. Remote exploitation of the attack is possible. A high degree of complexity is needed for the attack. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The user management section of the web application permits the creation of user accounts with excessively weak passwords, including single-character passwords. |
| Quantum SuperLoader 3 V94.0 005E.0h devices allow attackers to access the hardcoded fa account because there are only 65536 possible passwords. |
| YMS VIS Pro is an information system for veterinary and food administration, veterinarians and farm. Due to a combination of improper method for system credentials generation and weak password policy, passwords can be easily guessed and enumerated through brute force attacks. Successful attacks can lead to unauthorised access and execution of operations based on assigned user permissions. This vulnerability affects VIS Pro in versions <= 3.3.0.6. This vulnerability has been mitigated by changes in authentication mechanisms and implementation of additional authentication layer and strong password policies.
|
| No password for the root user is set in Novakon P series. This allows phyiscal attackers to enter the console easily.
This issue affects P series: P – V2001.A.C518o2 until P-2.0.05 Build